Reversing
Polarity DC Contactor Specifications |
| |
24 Volt
(also available in 12 Volt) |
| Relay Type: |
Motor reversing with dynamic braking in deenergized state. |
| Physical Size: |
Approx. 5.0" x 2.45" x 2.05" without terminal
projections. |
| Environmental: |
Operating ambient temperature range: -40 F° to 140 F°.
Relay is dust and splash
resistant to oil, gasoline, antifreeze, common cleaning solutions
and brake fluids. |
| Coil Voltage Operating Ratings: |
Operating, Nominal: 24VDC (Nominal Coil Resistance is 25.5 Ohms
@ 25° C)
Operating, Min / Max 15 VDC - 30 VDC @ 25 C° Coil Temp
Pull-in, Min @ 25 C° Coil Temp: 15 VDC
Hold Voltage, Max @ 25 C° Coil Temp: 5.0 VDC
Pull-in, Typical, Hot (after 5 minutes continuous operating @
rated voltage
@ 25 C° Ambient): 23.0 VDC
Hold Voltage, Max, Hot (after 5 minutes operating @ rated Voltage
@ 25° C
Ambient): 10.0 VDC |
| Contact Voltage Ratings: |
Operating, Nominal: 24 VDC
Operating, Max: 30 VDC |
| Contact Current Ratings (both contact sets): |
75 Amps carry for 5 minutes Max.
125 Amps carry for 30 sec.
150 Amps In Rush 1 |
| Contact(s) Electrical Life Rating, Inductive Load: |
10,000 cycles @ 150 Amp in Rush 1 75 Amp carry (5.0 sec. On,
25 sec. OFF) |
| Max. Sustained Duty Cycle: |
20% |
| Max. Sustained On Time: |
5 minutes 2 |
| Electrical Connection: |
Two Low Current (LC) terminals for two coils, both coils grounded
to main
battery ground terminal. Four high current (HC) terminals, two
for motor and
two for battery. HC terminals 5/16-24 studs. Low Current (LC)
terminal 1/4"
spade terminals. |